Routing
Highlighted
Routing

dynamic profile on Mx

[ Edited ]
3 weeks ago

Hi all,

Any ideas why I am getting the following commit error?

 

bngMx480# commit check
re0:
[edit interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLANs-Demux-LBN]
'ranges 832-832,any'
Only one profile is allowed if the number of ranges exceeds 32
error: configuration check-out failed

 

 

 

 

7 REPLIES 7
Highlighted
Routing

Re: dynamic profile on Mx

3 weeks ago

Hi Arix,

 

Could you provide config that you  for the below :

 

 interfaces ae100

 

&

 

AUTO-Stack-VLANs-Demux-LBN

 

Best Regards,

Mohamed

Highlighted
Routing

Re: dynamic profile on Mx

3 weeks ago

Hi Arix,

 

you maybe trying to add more than one dymanic profile so the limit will be 32 range only.

 

If this solves your problem, please mark this post as "Accepted Solution."

Regards,
A.A.
Highlighted
Routing

Re: dynamic profile on Mx

3 weeks ago

Hello Arix, 

 

Greetings,

As per our documentation, you can configure multiple dynamic profile associations (up to 32) with different VLAN range groups on each physical interface.

 

Verify the config as mohamed said. Check the step 6 in the link : https://www.juniper.net/documentation/en_US/junos/topics/task/configuration/subscriber-management-st...

 

Hope this helps. :grinning_face:

 

Please mark "Accept as solution" if this answers your query.  Kudos are appreciated too! 

 

Regards, 

Sharat Ainapur

 

Highlighted
Routing

Re: dynamic profile on Mx

[ Edited ]
3 weeks ago

Thanks for the replies..

I checked the step 6 in link that you provided...

In current configuration on the device,  there are more than 32 following statement of profile of the AUTO-Stack-VLAN-Demux-PROF1 with different ranges. IS this problem?  

....

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges

1200-1200,any

....

.....

....

Highlighted
Routing

Re: dynamic profile on Mx

3 weeks ago

Hi Arix,

 

It should not be more than 32 for the single phyiscal interface, otherwise you would get the commit error. It could be more than 32  for more than one single interface.

 

"You can configure multiple dynamic profile associations (up to 32) with different VLAN range groups on each physical interface."

 

Please mark "Accept as solution" if this answers your query.

Best Regards,

Mohamed

Highlighted
Routing

Re: dynamic profile on Mx

[ Edited ]
3 weeks ago

 

 

I checked and the following statements are more than 32.  What workaround should be? And what is impact then fixing this problem in production?

 

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1200-1200,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1220-1220,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1225-1225,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1235-1235,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1236-1236,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1250-1250,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1255-1255,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1350-1350,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 1850-1850,any

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 2000-2000,any

....

.......

........

set interfaces ae100 auto-configure stacked-vlan-ranges dynamic-profile AUTO-Stack-VLAN-Demux-PROF1 ranges 2550-2550,any

Highlighted
Routing

Re: dynamic profile on Mx

3 weeks ago

Hi Arix,

 

You can try to combine some of these ranges together. If is ok for you, you can try this during MW.

 

 

Please mark "Accept as solution" if this answers your query.

Best Regards,

Mohamed

Feedback